AELAB Manual Normal Adjustable 8 channel Pipette
AELAB Manual Normal Adjustable 8 channel Pipette
AELAB Manual Normal Adjustable 8 channel Pipette
AELAB Manual Normal Adjustable 8 channel Pipette
AELAB Manual Normal Adjustable 8 channel Pipette

AELAB Manual Normal Adjustable 8 channel Pipette

Model NO.
AE-8M10 AE-8M50 AE-8M300
+ 8 and 12 channel pipettes are available for standard 96-well plate
+ Dispensing head rotates for optimum pipetting convenience
+ Individual piston and tip cone assemblies allow easy repair and maintenance
+ Compound material tip cone design allows visual seal verification
+ Can be used with universal style pipette tips
Quantity:

AELAB Manual Normal Adjustable 8 channel Pipette AE-8M10 AE-8M50 AE-8M300

Mechanical Pipettes (Adjustable & Fixed)
All pipettes have been quality tested according to ISO8655-2:2002 with calibration certificate. The quality control involves

gravimeter testing of each pipette with distilled water at 22℃  .

Manual Pipette Type
+ Normal Adjustable/Fixed Manual 1,8,12 Channels Pipette (Non-Sterile)
+ Half Autoclave Adjustable/Fixed Manual 1,8,12 Channels Pipette
+ Fully Autoclave Adjustable/Fixed Manual 1,8,12 Channels Pipette

Features for Single Channel
- Lightweight, ergonomic, low force design
- Digital display clearly reads volume setting
- The pipettes cover volume range of 0.1μl to 10ml
- Easy to calibrate and maintain with tool supplied
- Design helps avoid repetitive strain injuries
- Calibrated in accordance with ISO8655. Each pipette supplied with individual test certificate
- The low part is available for autoclaving
- Manufactured from innovative materials


Features for Muti-channels

- 8 and 12 channel pipettes are available for standard 96-well plate
- Dispensing head rotates for optimum pipetting convenience
- Individual piston and tip cone assemblies allow easy repair and maintenance
- Compound material tip cone design allows visual seal verification
- Can be used with universal style pipette tips




Technical Specifications
 
8-channels Adjustable Volume Pipettes
PictureModelVolume range IncrementTest Volume Maximum permissibleMaximum Permissible
systematic error random error
(Inaccuracy)(Imprecision)
(μl)%μl%μl
AE-8M100.5-10μL0.1μL10μL1.50%0.151.50%0.15
5μL2.50%0.1252.50%0.125
1μL4.00%0.044.00%0.04
AE-8M505-50μL0.5μL50μL1.00%0.50.50%0.25
25μL1.50%0.3751.00%0.25
5μL3.00%0.152.00%0.1
AE-8M30050-300μL5μL300μL0.70%2.10.25%0.75
150μL1.00%1.50.50%0.75
50μL1.50%0.750.80%0.4





 

Send Message

* clear input
* clear input
* clear input
* clear input
*
*

Related Products

Model NO. AE-MF01 AE-MF02 AE-MF03 AE-MF04 AE-MF05 AE-MF06 AE-MF07 AE-MF08 AE-MF09 AE-MF10 AE-MF11 AE-MF12
Model NO. AE-MA01 AE-MA02 AE-MA03 AE-MA04 AE-MA05 AE-MA06 AE-MA07 AE-MA08 AE-MA09 AE-MA10 AE-MA11
customer-service Customer Service
skype Skype
message Message
go top Top
A & E Lab (UK) Co.,Ltd
Scan the QR code Close
qr code
qrcode

Send Message

* clear input
* clear input
* clear input
* clear input
*
*
Choose language