AELAB Drug Stability Testing Chamber AE-DT Series
Drug Stability Test Chamber is used in food industry also basic used in advanced research, Pharmaceutical Drug stability testing point, chemical industries, and including testing products relating to aerospace, electronics, automobile and environmental stress screening etc.
AE-DT150SDP AE-DT150GSP AE-DT250SDP AE-DT250GSP AE-DT500SDP AE-DT500GSP AE-DT1000SDP AE-DT1000GSP
Quantity:
Drug Stability Testing Chamber
Drug Stability Test Chamber is used in food industry also basic used in advanced research, Pharmaceutical Drug stability testing point, chemical industries, and including testing products relating to aerospace, electronics, automobile and environmental stress screening etc.
Drug Stability Test Chamber is used in food industry also basic used in advanced research, Pharmaceutical Drug stability testing point, chemical industries, and including testing products relating to aerospace, electronics, automobile and environmental stress screening etc.
Features:
+Equipped with large touch control screen, touch screen ≥7 inches.Real-time monitoring of operating status, can display the current temperature (humidity),temperature (humidity) set value, date, time, temperature (humidity) curve and other operating parameters.
+Patent double greenhouse temperature control system, greatly improve the temperature uniformity in the chamber.
+With data storage function, can store 100,000 data.
+With user rights classification function, can be divided into craft and operator two user levels.Operator rights: view interface information, alarm and data curve functions.Process authority: including operator authority, setting process parameters, regional interface operation function, start and stop preset program, report query, operation record event query.
+With intelligent frost system, frost does not affect the performance of equipment.
+Reservation switch function.
+The use of domestic well-known brand silent fan, unique design of air duct, to create a good air circulation convection, to ensure the uniformity of temperature.
Implement and meet standards:
+Pharmacopoeia 2020 edition drug stability test guidelines and GB/T10586-2006 related provisions manufactured.
+Stability test conditions
+Storage conditions of long-term retention samples for stability tests
+Temperature: + 2 ℃ to 25 ℃ +
+Humidity: 60 + / - 5% RH
+Time: 12 months
+Storage conditions of accelerated stability test
+Temperature: + 40 ℃ + 2 ℃
+Humidity: 75 + / - 5% RH
+Time: 6 months
Options:
- Remote alarm -- convenient for customers to know the equipment at any time.
- Independent temperature limit alarm system -- when the temperature exceeds the limit, the heating source will be forcibly stopped to ensure the safety of your laboratory.
Specifications:
#drug stability test chamber
#medicine stability testing chamber
#drug stability testing
#stability chamber
Model | AE-DT150SDP AE-DT150GSP | AE-DT250SDP AE-DT250GSP | AE-DT500SDP AE-DT500GSP | AE-DT1000SDP AE-DT1000GSP |
TemperatureRange | 0~65℃ | |||
Fluctuation | ±0.2℃ | |||
TemperatureUniformity | ±0.5℃ | |||
Humidity Range | 25~95%RH | |||
Humidity Accuracy | ±3%RH | |||
IlluminationIntensity | 0~6000LX adjustable ≤±500LX (ten level dimming, each level 600LX, precise control intensity) Test distance 200mm (GSP function) | |||
Timing | 30 stages 99 cycles/each stage 1-99 hours | |||
TheLightSourcePlate | GSP model with light plate | |||
TemperatureAndHumidityControlMode | Balanced temperature and humidity control mode | |||
Controller | Large screen touch screen controller | |||
UltravioletEnergyLamp (optional) | Uv spectrum range 320~400nm | |||
RefrigerationSystem CoolingWay | Automatic electronic expansion valve refrigeration control system/ imported Danvers compressor | |||
Temperature/HumiditySensor | Pt100 platinum resistor/imported Austrian E+E humidity sensor | |||
AmbientTemperature | RT+5~30℃ | |||
PowerSupply | AC 220V±10% 50HZ | AC 380V±10% 50HZ | ||
Power | 1900W | 2200W | 3200W | 4500W |
Volume | 150L | 250L | 500L | 1000L |
InnerDimension A×B×C(mm) | 480×400×780 | 580×500×850 | 800×700×900 | 1050×590×1610 |
OuterDimension D×E×F(mm) | 645×755×1450 | 745×855×1550 | 1000×1100×1860 | 1410×890×1950 |
Shelves (standard) | 2PCS | 3PCS | 4PCS | |
EmbeddedPrinter | Standard | |||
USBInterface | Standard | |||
SafetyDevice | Compressor overheat protection, overtemperature protection, compressor overpressure protection, overload protection, water shortage protection | |||
Executive Standard | Guidelines for drug stability Test of 2015 edition of Pharmacopoeia and relevant manufacturing provisions of GB/10586-2006 |
#medicine stability testing chamber
#drug stability testing
#stability chamber