AELAB Ion Chromatograph CIC-D120
+Temperature-control bipolar conductivity detector Greater detection range,better precise analysis
+Built-in circulating 3D constant temperature technology Temperature stability time is less than 30 mins, ensuring the accuracy and reliability of test data
+The world's leading full-range series of ion chromatographic columns High efficiency, large capacity of the columns for detecting ions of varied compositions
+Built-in circulating 3D constant temperature technology Temperature stability time is less than 30 mins, ensuring the accuracy and reliability of test data
+The world's leading full-range series of ion chromatographic columns High efficiency, large capacity of the columns for detecting ions of varied compositions
CIC-D120
1
Quantity:
AELABCIC-D120IonChromatograph
Features:
#liquid chromatograph
#hplc chromatograph
Features:
+Temperature-control bipolar conductivity detector Greater detection range,better precise analysis
+Built-in circulating 3D constant temperature technology Temperature stability time is less than 30 mins, ensuring the accuracy and reliability of test data
+The world's leading full-range series of ion chromatographic columns High efficiency, large capacity of the columns for detecting ions of varied compositions
+Self-Regenerating ElectrolyticMicro-membrane Suppressor.
+High pressure resistance, small dead volume, highly responsive to signals
+Able to detect anions and cations at the ppb level
+Work across a variety of detectors, to expand the scope of applications of ion chromatography.
Technical Parameter:Ion Chromatographic Pump | Type | High-pressure and low-pulse two-piston tandem advection pump |
Maximum Pressure | 42MPa | |
Pressure Display Accuracy | ≤0.1MPa | |
Flow Stability | (0.2-0.5)mL/min≤3%; (0.5-1.0)mL/min≤2%; >1.0mL/min≤2%; | |
Allowable Deviation of Flow | (0.2-0.5)mL/min , ±5%; (0.5-1.0)mL/min, ±3%; >1.0mL/min, ±2%; | |
Flow Range | 0.001~9.999mL/min | |
Pressure Pulse | ≤0.5% | |
Flow Precision | ≤0.1% | |
Flow Accuracy | ≤0.1% | |
Numerical-control and Electromagnetic Sample Injector | Maximum Pressure | 35MPa |
Contact Material of the Rotor | PEEK | |
Control Mode | By Stepper motor | |
Power Supply | 24V (DC) | |
Suppressor | Type | Self-Regenerating electrolytic micro-membrane suppressor |
Maximum Pressure | 6.0MPa | |
Dead Volume | <50μL |
Digital and Temperature- control Detection System | Conductivity Detector | Type | Temperature--control and bipolar conductivity detector |
Detection Mode | Bipolar conductivity detection | ||
Cell Volume | ≤0.8μL | ||
Detection Range | 0~45000μS/cm | ||
Detection Resolution | ≤0.0020nS/cm | ||
Output Voltage | -6000~+6000mV (adjustable) | ||
Electronic Noise | 0.02nS | ||
Baseline Noise | ≤0.001μS | ||
Baseline Drift | ≤0.01μS | ||
Operating Temperature Range | Room temperature +5 ℃~60 ℃±0.01℃ | ||
Controlling Temperature Accuracy | ±0.01 ℃ | ||
Maximum Pressure | 10.0MPa | ||
Linear Range | ≥103 | ||
Instrument Linearity | ≥0.999 | ||
Quantitative Repeatability | ≤0.5% | ||
Qualitative Repeatability | ≤0.5% | ||
Minimum Detectable Concentration | Cl-≤0.0002ug/mL; Li+≤0.0002ug/mL | ||
Flow System | Plastic Flow Path | Made of PEEK materials | |
Six-way Valve | PEEK material, pressure 5000psi;Independent automatic collecting and flow function. | ||
Power Supply | 150W | ||
External Size(L*W*H*) | 350*470*510(mm) | ||
Net Weight(KG) | 26 | ||
Gross Weight(KG) | 32 |