AELAB Single Channel Electronic Pipette,pipette electronic,electronic pipette,8 channel pipette,pipette,single channel,AELAB Single Channel Electronic Pipette,pipette electronic,electronic pipette,8 channel pipette,pipette,single channel,Single Channel Electronic Pipette,AELAB Magnetic Hotplate Stirrers AHO-101,hotplate stirrers,magnetic stirrers,hotplate,hotplate magnetic stirrer,magnetic stirrer hotplate,AELAB_Magnetic_Hotplate_Stirrers_AHO_101,hotplate stirrers,magnetic stirrers,hotplate,hotplate magnetic stirrer,magnetic stirrer hotplate,AELAB_Magnetic_Hotplate_Stirrers_AHO_101,AELAB Magnetic Hotplate Stirrers AHO-102,hotplate stirrers,magnetic stirrers,hotplate,hotplate magnetic stirrer,magnetic stirrer hotplate,AELAB-Magnetic-Hotplate-Stirrers-AHO-102,hotplate stirrers,magnetic stirrers,hotplate,hotplate magnetic stirrer,magnetic stirrer hotplate,AELAB-Magnetic-Hotplate-Stirrers-AHO-102

nucleic acid
nucleic acid Protein Detector AE-3001
Fraction Collector AE-Blupad FC is one of the basic equipment for biochemistry experiments and biological drug production. It is used to automatically and quantitatively collect the liquid droplets from the chromatography column to achieve the purpose of packing different active groups into different tubes.
AE-3001
Quantity:

NucleicAcidProteinDetectorAE-3001

1. Product introduction

Fraction Collector AE-Blupad FC is one of the basic equipment for biochemistry experiments and biological drug production. It is used to automatically and quantitatively collect the liquid droplets from the chromatography column to achieve the purpose of packing different active groups into different tubes.

2.Fraction Collector Model AE-BLUPAD FC Product Features:

Parameters can be arbitrarily set, set the first pipe, the end pipe;7"capacitive liquid crystal touch screen display and control;It can be collected according to time, drops, peak value and program control (independent use). Collect by volume and threshold by running Blupad 1.0 control software online. (Online)Corrosion resistance design: suitable for separation of water-soluble solvents and organic solvents by column chromatography.65° bevel control panel design, ergonomic, can be easily controlled without bending over.Adopt square design and suspension type X-Y movement mode, accurate positioning of pipe change;

3. Technical parameters of Fraction Collector:

Display mode: LCD Chinese blue screen display

Collection tube: 100 tubes, each with a capacity of 12ml (standard), 16 tubes, each with a capacity of 100ml (optional), 36 tubes, each with a capacity of 50ml (optional), 169 tubes, each with a capacity of 5ml(optional)

Timing range: 1 second - 999 hours 59 minutes 59 seconds optional

Fixed drop range: 1 drop - 9999 drop optional

Fixed peak range 1-200mV optional

Program control range 1-10 sections optional

Movement mode: suspension X - Y movement

Pipe change control: 12V DC solenoid valve

Operation mode: Chinese menu type

Number of programs: 1-10 / mode

Display mode: Chinese LCD large blue film LCD display

Test-tube tray holder: square design with waste liquid tank, free combination, optional

Power outage data storage: 10 years

Continuous working time: more than 200 hours

#protein nucleic acid

#nucleic acid

#nucleic acid protein

#nucleic acid

#acid nucleic acid

#nucleic acid

#protein nucleic acids