AELAB Single Channel Electronic Pipette,pipette electronic,electronic pipette,8 channel pipette,pipette,single channel,AELAB Single Channel Electronic Pipette,pipette electronic,electronic pipette,8 channel pipette,pipette,single channel,Single Channel Electronic Pipette,AELAB Magnetic Hotplate Stirrers AHO-101,hotplate stirrers,magnetic stirrers,hotplate,hotplate magnetic stirrer,magnetic stirrer hotplate,AELAB_Magnetic_Hotplate_Stirrers_AHO_101,hotplate stirrers,magnetic stirrers,hotplate,hotplate magnetic stirrer,magnetic stirrer hotplate,AELAB_Magnetic_Hotplate_Stirrers_AHO_101,AELAB Magnetic Hotplate Stirrers AHO-102,hotplate stirrers,magnetic stirrers,hotplate,hotplate magnetic stirrer,magnetic stirrer hotplate,AELAB-Magnetic-Hotplate-Stirrers-AHO-102,hotplate stirrers,magnetic stirrers,hotplate,hotplate magnetic stirrer,magnetic stirrer hotplate,AELAB-Magnetic-Hotplate-Stirrers-AHO-102

alt="{AELAB}{Total Organic Carbon Analyzer}-{AE-TOC-2000}"
AELAB Total Organic Carbon Analyzer
Total Organic Carbon Analysis has been an analytical technique used to measure water quality in the water supply industry since in the early 1970s.
AE-TOC-2000
Quantity:

AE-TOC-2000 Total Organic Carbon Analyzer

Total Organic Carbon Analysis has been an analytical technique used to measure water quality in the water supply industry since in the early 1970s.

Features:

+ Signal management system of our own national patent which has great advantages of online setting, real-time monitoring, self-testing and flow speed controlling ensure high performance and safe operation.
+ Low current system design ensures users safety.
+ Different temperature setting for various samples ensures complete sample digestion so as to get more accurate measuring data.
+ Adjust cooling module power according to sampling volume which improves drying performance to ensure dry gas into the detector.
+ Automatic leaking check system to avoid operation mistakes, also improves instrument performance and ensures operation safety.
+ Flow rate controlling system to avoid any effect caused by flow rate fluctuation which ensures accurate data.
+ TOC detector with 24 bits data solution extends monitoring range.Controlling system with 32bin processing technology greatly improves performance.

Technical Specifications:

Model

AE-TOC-2000

Detector

NDIR

Parameters

TC, TIC, TOC, NPOC

Digestion Mode

High Temperature Combustion

Operation Mode

PC Control

Application

Liquid Sample

Gas Requirement

Oxygen ≥ 99.995%

Measurement Range

0-30000mg/l (ppm)

Detection Limit

50μg/l (ppb)

Repeatability

3%

Maximum Salinity

85g/l

Power

AC220V, 50Hz or AC110V, 60HZ, 200W

Size

430*455*440mm

#total organic carbon analyzer
#analyzer organic