AELAB Single Channel Electronic Pipette,pipette electronic,electronic pipette,8 channel pipette,pipette,single channel,AELAB Single Channel Electronic Pipette,pipette electronic,electronic pipette,8 channel pipette,pipette,single channel,Single Channel Electronic Pipette,AELAB Magnetic Hotplate Stirrers AHO-101,hotplate stirrers,magnetic stirrers,hotplate,hotplate magnetic stirrer,magnetic stirrer hotplate,AELAB_Magnetic_Hotplate_Stirrers_AHO_101,hotplate stirrers,magnetic stirrers,hotplate,hotplate magnetic stirrer,magnetic stirrer hotplate,AELAB_Magnetic_Hotplate_Stirrers_AHO_101,AELAB Magnetic Hotplate Stirrers AHO-102,hotplate stirrers,magnetic stirrers,hotplate,hotplate magnetic stirrer,magnetic stirrer hotplate,AELAB-Magnetic-Hotplate-Stirrers-AHO-102,hotplate stirrers,magnetic stirrers,hotplate,hotplate magnetic stirrer,magnetic stirrer hotplate,AELAB-Magnetic-Hotplate-Stirrers-AHO-102

alt="{Laboratory Turbidity Meter }-{TB200}"
AELAB Laboratory Turbidity Meter TB200
Turbidimeter is an on-line monitoring instrument designed for measuring the turbidity of municipal sewage and industrial wastewater treatment.
TB200
Quantity:

Laboratory Turbidity Meter TB200

Turbidimeter is an on-line monitoring instrument designed for measuring the turbidity of municipal sewage and industrial wastewater treatment.

Features:

+ 2 to 7 points calibration using the Formazin Standards
+ Selectable 4 turbidity units, including the NTU, FNU, EBC and ASBC
+ TSS conversion factor ensures the accurate measurement of the total suspended solids
+ Auto-Read function senses and locks a stable reading
+ Setup menu allows setting the date and time, measurement mode, resolution, etc.
+ Reset function automatically resumes all settings back to the factory defaults
+ Password protection prevents the unauthorized calibration and settings
+ Expanded memory stores or recalls up to 200 data sets
+ USB communication interface is easy to transfer data to PC

Technical Specifications:

Model

TB200

Turbidity

Range

0~2000NTU, 0~500 EBC, 0~9999ASBC

Resolution

0.01 (0~99NTU), 0.1 (100~999NTU), 1 (1000~2000NTU)

Accuracy

±2% of reading (0~500NTU), ±3% of reading (501~2000NTU)

Calibration Points

2 to 7 points

Calibration Standards

0.02, 10, 200, 500, 1000, 1500, 2000NTU

TSS

Range

Deponding on the TSS conversion factor

Accuracy

3% of reading

Other Specifications

Light Source

Infrared-emitting diode (850nm wavelength)

Detector

Silicon photodiode

Stray Light

<0.02 NTU

Sample Vial

60(H)× 25 (Dia)mm

Memory

200 data sets

Communication Interface

USB

Operating Temperature

0~50°C

Display

4.5 inches TFT LCD

Power Requirements

DC12V power adapter

Dimensions

250 (L)× 177 (W)×96 (H)mm

Weight

1.2kg