AELAB Single Channel Electronic Pipette,pipette electronic,electronic pipette,8 channel pipette,pipette,single channel,AELAB Single Channel Electronic Pipette,pipette electronic,electronic pipette,8 channel pipette,pipette,single channel,Single Channel Electronic Pipette,AELAB Magnetic Hotplate Stirrers AHO-101,hotplate stirrers,magnetic stirrers,hotplate,hotplate magnetic stirrer,magnetic stirrer hotplate,AELAB_Magnetic_Hotplate_Stirrers_AHO_101,hotplate stirrers,magnetic stirrers,hotplate,hotplate magnetic stirrer,magnetic stirrer hotplate,AELAB_Magnetic_Hotplate_Stirrers_AHO_101,AELAB Magnetic Hotplate Stirrers AHO-102,hotplate stirrers,magnetic stirrers,hotplate,hotplate magnetic stirrer,magnetic stirrer hotplate,AELAB-Magnetic-Hotplate-Stirrers-AHO-102,hotplate stirrers,magnetic stirrers,hotplate,hotplate magnetic stirrer,magnetic stirrer hotplate,AELAB-Magnetic-Hotplate-Stirrers-AHO-102

alt="{AELAB}{Gelatin Gel strength test system}-{AE-JS-II}"
AELAB Gelatin Gel Strength Test System
Gelatin Gel strength test system is mainly used to measure the gel strength of gelatin under the stipulated environment. It consists of: Jelly Strength, Constant Temperature Bath, Refrigerator.
AE-JS-II
Quantity:

Gelatin Gel strength test system

Gelatin Gel strength test system is mainly used to measure the gel strength of gelatin under the stipulated environment. It consists of: Jelly Strength, Constant Temperature Bath, Refrigerator.

Advantage

+ High-definition LCD Display.
+ Powerful data processing ability: submit mean value, final value or peak value automatically.
+ Four kinds of sampling measurement modes: single-step, maintaining, circulating and automatic.
+ Automatic measurement mode can help you obtain the value of gel strength faster, more accurately and more realistically.
+ 5 kinds of sampling speeds: 0.1mm/s, 0.2mm/s, 0.5mm/s, 1mm/s and 2mm/s.
+ Sampling depth can be preset arbitrarily (1~60mm).
+ Professional high-precision pressure sensor.
+ High-precision mechanical drive matches with 4-class shockproof design
+ Automatic correction of non-linear error, automatic fault diagnosis alarm, automatic outrange protection and automatic error correction prompt.

Specification

Model

AE-JS-II

Test Range

5~1000 Bloomg

Test Accuracy Range

±0.3%

Resolution

1Bloomg

Travel

1~60mm

Travel Accuracy

≤±0.1mm

Measured Diameter of Cylinder

12.700±0.010mm

Standard Gel Strength Bottle(diameter*height)

59*85mm, 150ml

Consumption

60W

Power Supply

AC110/220V±10%, 50/60Hz

Overall Dimensions(L*W*H)mm

260*260*450

Packing Size(L*W*H)mm

405*360*530

Gross Weight(kg)

12