AELAB Single Channel Electronic Pipette,pipette electronic,electronic pipette,8 channel pipette,pipette,single channel,AELAB Single Channel Electronic Pipette,pipette electronic,electronic pipette,8 channel pipette,pipette,single channel,Single Channel Electronic Pipette,AELAB Magnetic Hotplate Stirrers AHO-101,hotplate stirrers,magnetic stirrers,hotplate,hotplate magnetic stirrer,magnetic stirrer hotplate,AELAB_Magnetic_Hotplate_Stirrers_AHO_101,hotplate stirrers,magnetic stirrers,hotplate,hotplate magnetic stirrer,magnetic stirrer hotplate,AELAB_Magnetic_Hotplate_Stirrers_AHO_101,AELAB Magnetic Hotplate Stirrers AHO-102,hotplate stirrers,magnetic stirrers,hotplate,hotplate magnetic stirrer,magnetic stirrer hotplate,AELAB-Magnetic-Hotplate-Stirrers-AHO-102,hotplate stirrers,magnetic stirrers,hotplate,hotplate magnetic stirrer,magnetic stirrer hotplate,AELAB-Magnetic-Hotplate-Stirrers-AHO-102

alt="{AELAB}{automatic polarimeter}-{AE-SGW-2 AE-SGW-1}"
AELAB Automatic Polarimeter
The instrument is widely used in sugar refining, pharmaceuticals, petroleum, food, chemical and a lot of industrial sectors and related institutions of colleges and research institutes.
AE-SGW-2 AE-SGW-1
Quantity:
Automatic Polarimeter
The instrument is widely used in sugar refining, pharmaceuticals, petroleum, food, chemical and a lot of industrial sectors and related institutions of colleges and research institutes.
 
+Need not prewarm when turning on;
+Measuring specific rotation, optical rotation, sugar degree and concentration;
+Peltier principle to control the temperature;
+Measurement of dark-colored sample;
+USB & RS232.
+Automatic repetition-measurement for 6 times, calculation of average value and means square root; 

Technical Specifications:
Parameters/ModelAE-SGW-2AE-SGW-1
Measurement modes:Optical rotation, specific rotation,
sugar degree, concentration
Optical rotation, specific rotation,
sugar degree, concentration
Light source:LED + interference filterLED + interference filter
Measurement range:±45°(optical rotation)
±120°Z (sugar)
±45° (optical rotation)
±120°Z (sugar)
Accuracy:±0.01° (-15° ≤optical rotation ≤+15°)
±0.02° (optical rotation<-15°
or optical rotation>+15°)
±0.01° (-15° ≤optical rotation ≤+15°)
±0.02° (optical rotation<-15°
or optical rotation>+15°)
Minimum indicating value:0.001°(optical rotation)0.001°(optical rotation)
sample transmittance:1%1%
Repeatability:0.002 °( optical rotation)0.002 °( optical rotation)
Display:7 Inch Colorful Touch LCD7 Inch Colorful Touch LCD
Operation Wavelength:589.44nm589.44nm
Temperature control range:15-30℃-----
Temperature Accuracy:±0.5℃-----
Test Tube:100mm/200mm (regular)  
100mm(temp control)
100mm/200mm (regular)
Interface:RS232/USBRS232/USB
Weight (Gross):43kg43kg
Overall Dimensions:820mm  500mm  510mm820mm  500mm  510mm
#automatic polarimeter
#digital polarimeter