AELAB Single Channel Electronic Pipette,pipette electronic,electronic pipette,8 channel pipette,pipette,single channel,AELAB Single Channel Electronic Pipette,pipette electronic,electronic pipette,8 channel pipette,pipette,single channel,Single Channel Electronic Pipette,AELAB Magnetic Hotplate Stirrers AHO-101,hotplate stirrers,magnetic stirrers,hotplate,hotplate magnetic stirrer,magnetic stirrer hotplate,AELAB_Magnetic_Hotplate_Stirrers_AHO_101,hotplate stirrers,magnetic stirrers,hotplate,hotplate magnetic stirrer,magnetic stirrer hotplate,AELAB_Magnetic_Hotplate_Stirrers_AHO_101,AELAB Magnetic Hotplate Stirrers AHO-102,hotplate stirrers,magnetic stirrers,hotplate,hotplate magnetic stirrer,magnetic stirrer hotplate,AELAB-Magnetic-Hotplate-Stirrers-AHO-102,hotplate stirrers,magnetic stirrers,hotplate,hotplate magnetic stirrer,magnetic stirrer hotplate,AELAB-Magnetic-Hotplate-Stirrers-AHO-102

alt="{AELAB}{incubator co2}-{AE-C160 AE-C80}"
AELAB CO2 Incubator
CO₂ incubators are most frequently used in medical research and in the pharmaceutical industry. However, the gassed incubators are also used in other areas where cells need to be grown in sterile conditions.
AE-C160 AE-C80
Quantity:

AELAB CO2 Incubator AE-C160 AE-C80

CO₂ incubators are most frequently used in medical research and in the pharmaceutical industry. However, the gassed incubators are also used in other areas where cells need to be grown in sterile conditions.

Features:
+Water jacket and air jacket structure are available, polished stainless-steel chamber with air duct. 
+Equipped with fan for forced convection, ensuring good temperature uniformity and the balance of CO2 concentration inside.
+PID microprocessor is used to control temperature,meanwhile,the temperature of box ,water and door are separately controlled by three probes to ensure high accuracy. ( Air jacket is equipped with two probes to control door temperature and main body temperature.)
+Digital display for setting parameters,each working state has LED indication.
+Alarm function for over-heating, lack of water, unaspirated, ensuring the safe operation of the equipment.
+Equipped with sterile air filtration devices and UV light system to reduce pollution.  
+Natural evaporation for humidification to ensure the chamber can maintain good humidity .
+The ratio of CO2 gas and air can be arbitrarily selected according to the needs, direct reading type flow meter, accurate and easy operation.


Specifications:
ModelAE-C80AE-C160
Chamber Volume(L80160
Temperature Range(℃RT+360
Temperature Stability(℃≤±0.2
Temperature Uniformity(℃≤±0.3
Timing Range19999min or without timing
CO2  Range020%
Humidity MethodNatural Vaporization
Power SupplyAC220V,50HZ
Power Rating(W600900
Chamber Size (W×D×H)cm40×40×5050×50×65
Exterior Size((W×D×H)cm57×59×9369×69×103
Package Szie(W×D×H)cm74×68×11085×75×125
Net/Gross Weight(kg55/8575/110
Shelf(Std/Max)2/93/13