N series spectrophotometer, being combined with and ARM processed core, has test speeds and functions possessed by high-end instruments. The instrument can meet the requirement of quantitative analysis for most samples conducted within the visible and ultraviolet-visible spectral range in concentional laboratories and is suitable for use in medicine and health, clinical examination, biochemical, petrochemical, environmental protection, quality contraol departments, colleges and universities and others.
Applications:
Novel series spectrophotometer, being combined with and ARM processed core, has test speeds and functions possessed by high-end instruments. The instrument can meet the requirement of quantitative analysis for most samples conducted within the visible and ultraviolet-visible spectral range in concentional laboratories and is suitable for use in medicine and health, clinical examination, biochemical, petrochemical, environmental protection, quality contraol departments, colleges and universities and others.
Features:
Technical Specifications:
Model | AE-N4S | AE-N4 | AE-N2S | AE-N2 |
Photometry | Single Beam | |||
Monochromator Type | Czerny-Turner | |||
Focal Length | 160mm | |||
Grating | 1200 lines/mm | |||
Detector | Silicon Photocell | |||
Spectrum Bandwidth | 2nm | 4nm | ||
Wavelength Range | 190-1100nm | 325-1100nm | ||
Wavelength Accuracy | ± 1nm | |||
Wavelength Repeatability | ≤ 0.5nm | |||
Photometric Range | 0.0 ~ 200.0% T ; -0.301 ~ 4.000A ; 0.000 to 9999C | |||
Photometric Accuracy | ± 0.3% T ; ± 0.002Abs (0 - 0.5A) ± 0.004Abs (0.5 - 1A) | ± 0.5% T | ||
Photometric Repeatability | ≤ 0.15% T ; 0.001Abs (0 - 0.5A) 0.002Abs (0.5 - 1A) | ≤ 0.2% T | ||
Wavelength Scanning Speed | Fast, medium, slow | --- | Fast, medium, slow | --- |
Baseline | ≤±0.003A(200-1090nm) | --- | ≤±0.003A(335-1090nm) | --- |
Built in Printer | YES | NO | YES | NO |
Stray Light | ≤ 0.1% ( at 220 nm NaI ; at 360 nm NaNO₂) | ≤ 0.1% T(measured at NaNO₂ at 360 nm) | ||
Noise | 100%(T) noise ≤ 0.5% (T), 0% (T) noise ≤ 0.2% (T) | |||
Baseline Drift | ± 0.002 Abs / 30 mins (250nm and 500nm after preheat warm up for 2 hours ) | ± 0.002 Abs /30min ( 500nm after preheat warm up for 2 hours ) | ||
Power | AC220v± 22v, 50Hz± 1Hz, 180W | AC220v± 22v, 50Hz± 1Hz, 100W | ||
Packing Size | 630mm*610mm*500mm, 0.16m³,25kg. |
Standrad Accessorie Optional Accessories