AELAB Single Channel Electronic Pipette,pipette electronic,electronic pipette,8 channel pipette,pipette,single channel,AELAB Single Channel Electronic Pipette,pipette electronic,electronic pipette,8 channel pipette,pipette,single channel,Single Channel Electronic Pipette,AELAB Magnetic Hotplate Stirrers AHO-101,hotplate stirrers,magnetic stirrers,hotplate,hotplate magnetic stirrer,magnetic stirrer hotplate,AELAB_Magnetic_Hotplate_Stirrers_AHO_101,hotplate stirrers,magnetic stirrers,hotplate,hotplate magnetic stirrer,magnetic stirrer hotplate,AELAB_Magnetic_Hotplate_Stirrers_AHO_101,AELAB Magnetic Hotplate Stirrers AHO-102,hotplate stirrers,magnetic stirrers,hotplate,hotplate magnetic stirrer,magnetic stirrer hotplate,AELAB-Magnetic-Hotplate-Stirrers-AHO-102,hotplate stirrers,magnetic stirrers,hotplate,hotplate magnetic stirrer,magnetic stirrer hotplate,AELAB-Magnetic-Hotplate-Stirrers-AHO-102

alt="{AELAB}{Plant Canopy analyzer}-{TOP-1000}"
AELAB Plant Canopy analyzer TOP-1000
​​​​​​​TOP-1000 Plant Canopy Analyzer is widely applied for farming production and agricultural research,canopy energy resource investigation, measure the light interception among plant canopy, and research the relation between plant growth & development, production quality and light utilization.The analyzer is used for measure and record the PAR value in wave band400nm-700nm , the measured value is 0-2700μmol ㎡/s
TOP-1000
Quantity:
Plant Canopy analyzer TOP-1000

Features:
TOP-1000 Plant Canopy Analyzer is widely applied for farming production and agricultural research,canopy energy resource investigation, measure the light interception among plant canopy, and research the relation between plant growth & development, production quality and light utilization.The analyzer is used for measure and record the PAR value in wave band400nm-700nm , the measured value is 0-2700μmol /s

Characteristic:
+Integration design, it includes LCD, operation buttons, SD card plug and measure probe.
+Menu operation is easy; small size and portable
+Large store capacity. Convenient data management.
+Low power dissipation with reasonable power management with automatically shut down and restarts action.
+Manual and auto measure method are available.

Technical Parameter:
Measuring Range0-2700μmol/s
Resolution1μmol/s
Response time10μs
Auto- collecting interval1-99minutes
Auto-collecting times1-99times
Store capacity2GBSD card
Meter length75 cm
Probe length50 cm
Qty of Sensors 25standard equipped
Power2*AA batteries
Working environment0°C-60°C100%HM
#
pc window canopy door canopy
#electric canopy
#canopy net