AELAB Single Channel Electronic Pipette,pipette electronic,electronic pipette,8 channel pipette,pipette,single channel,AELAB Single Channel Electronic Pipette,pipette electronic,electronic pipette,8 channel pipette,pipette,single channel,Single Channel Electronic Pipette,AELAB Magnetic Hotplate Stirrers AHO-101,hotplate stirrers,magnetic stirrers,hotplate,hotplate magnetic stirrer,magnetic stirrer hotplate,AELAB_Magnetic_Hotplate_Stirrers_AHO_101,hotplate stirrers,magnetic stirrers,hotplate,hotplate magnetic stirrer,magnetic stirrer hotplate,AELAB_Magnetic_Hotplate_Stirrers_AHO_101,AELAB Magnetic Hotplate Stirrers AHO-102,hotplate stirrers,magnetic stirrers,hotplate,hotplate magnetic stirrer,magnetic stirrer hotplate,AELAB-Magnetic-Hotplate-Stirrers-AHO-102,hotplate stirrers,magnetic stirrers,hotplate,hotplate magnetic stirrer,magnetic stirrer hotplate,AELAB-Magnetic-Hotplate-Stirrers-AHO-102

alt="{AELAB}{IR Spectrophotometer}-{TJ270-30A}"
AELAB Dual Beam IR Spectrophotometer TJ270-30A
Infrared spectroscopy is one of the most powerful techniques for identifying organic substances in organic and analytical chemistry. Infrared analysis can be both qualitative and quantitative. TJ270-30A is an important tool in analytical laboratories.
TJ270-30A
Quantity:
TJ270-30A Dual Beam IR Spectrophotometer
Features:
High quality
Low stray light
High accuracy measurement
Simple structure with easy operation

Introduction:
Infrared spectroscopy is one of the most powerful techniques for identifying organic substances in organic and analytical chemistry. Infrared analysis can be both qualitative and quantitative. TJ270-30A is an important tool in analytical laboratories.

It can be used to record the IR absorption and reflectance spectra of substances in the spectral range of 4000 ~ 400 cm-1. It is a powerful tool to analyze sample structures in the fields such as petroleum, chemical engineering, pharmacy, public health and environmental protection.

The Windows application software provides a user-friendly interface for the control of the spectrophotometer, data acquisition, and spectral analysis with functions listed below:
Spectral background baseline memory
Spectral background baseline correction
Spectral data smoothing operation
Spectral baseline slope correction
Spectral data differential operation
Spectral data arithmetic operation
Spectral data accumulating operation
Conversion of %T and Abs
Spectrum file management
Spectral peak search
Spectrum scale extension
Spectral absorption expansion
Technical Specifications:
Optical systemDouble-beam
Wave-numberRange4000-400cm-1
Transmittance (%)0—100.0%
Absorbency0—3Abs
Power SourceAC 220V±10%50±1 Hz300W
Wave-number Accuracy≤±4cm-1(4000—2000cm-1),≤±2(2000—400cm-1)
WN Repeatability≤2cm-1(4000—2000cm-1),≤1cm-1(2000—400cm-1)
Transmittance Accuracy≤±0.5%(noise level not included)
Transmittance Repeatability≤0.5%(1000—930cm-1)
Io Line Flatness and Straightness≤4%
Resolution CapabilityPolystyrene has six absorption peaks around 3000cm-1with height of 1% at least; Ammonia gas’s resolution is 2.5cm-1 around 1000 cm-1, with height of 1% at least.
Stray Lights≤1% (4000—650cm-1),≤2%(650-400cm-1)
Slit Width5 steps
DimensionsMainframe: 800mm´610mm´300mm
Weight80kg or so
#double beam uvvis spectrophotometer
#beam spectrophotometer
#spectrophotometer uv vis spectrophotometer
#double beam spectrophotometer